Hospital Nursing Elderly Care Anti-Bedsore Inflatable Mattress

Still deciding? Get samples of $ !
Request Sample

Product Description

i

Basic Information

Model NO.
YQ-QD-01
Theory
Electrotherapeutics
Certification
ISO13485
LCD Display
Without LCD Display
Group
Adult
Material Quality
Medical PVC
Packaging Size
L39*W24*H37
Transport Package
Carton
Specification
2000*900
Trademark
JIYUNQI
Origin
China
HS Code
3926909090
P

Product Principle

The principle of air mattress fluctuation

The mattress itself has two chambers, with a single trachea using a single chamber. Dual air pipes use dual chambers. Using another chamber, the air mattress works continuously through an air pump for a long time to inflate and exhaust, achieving a fluctuating effect. Two chambers circulate for exhaust and inflation. When a single chamber is deflated, the air pump will automatically change air after a few minutes, becoming a double chamber deflated, and the single chamber is full, constantly changing the area of force on the human body.

D

Detailed Craftsmanship

Independent airbags
Independent airbags The airway can be removed separately, and if damaged, it can be easily replaced.
Seamless design
Seamless design Seamless hot press sealing, embedded joints, good sealing performance.
Circulatory airway
Circulatory airway Alternating ventilation to achieve fluctuating contact with the skin, effectively preventing the growth of pressure ulcers.
Silicone nozzle connector
Silicone nozzle connector Long service life, clean and hygienic, strong sealing performance.
Concealed airbag
Concealed airbag Can be disassembled separately for easy cleaning and easy replacement.
G

Instructions for Use

1
Lay the air mattress flat on the bed (no foreign objects on surface). Air inlet should be at patient's feet.
2
Place air pump on desktop or 20cm above ground. Connect power, turn knob clockwise (green light on).
3
Connect blue air duct to the pump outlet and the mattress intake nozzle. Ensure no leaks.
4
After 15-20 minutes of inflation, the pressure will reach normal usage status.
5
Release side buttons during urination/defecation; use the small air cushion at the toilet hole.
6
For quick deflation, stop the pump and unplug the air duct.
8
For sleep mode, turn knob counterclockwise. The mattress will stop fluctuating and remain stationary.
Usage detail 1
Usage detail 2
Usage detail 3
Usage detail 4
M

Maintenance of Air Cushion

A
Surface Cleaning: Regularly clean with neutral detergent; avoid acids and alkalis.
B
Storage: Empty gas, clean bottom/chambers, fold in original box. Store in dry, ventilated room (-20°C to +55°C).
C
Disinfection: Wash sheets/covers with 500mg/L chlorine dioxide solution for 30 mins, rinse and dry.
Maintenance 1
Maintenance 2
Maintenance 3
?

Frequently Asked Questions

How does the fluctuating air mattress prevent bedsores?
It uses a two-chamber circulation system that alternates inflation and deflation, constantly changing the pressure points on the patient's body to promote blood circulation and prevent pressure ulcers.
What should I do if a single airbag is damaged?
The mattress features independent airbags. You can easily remove the damaged airway separately and replace it without replacing the entire mattress.
How long does it take to fully inflate the mattress?
Under normal conditions, it takes approximately 15-20 minutes for the air pump to reach the standard usage pressure.
Can I use the mattress while the patient needs to use the toilet?
Yes, the mattress includes a convenient toilet hole design. You can release the side buttons and open the small air cushion at the toilet hole for easy access.
What are the storage requirements when not in use?
The mattress should be deflated, cleaned, and stored in a dry, ventilated environment with temperatures between -20°C and +55°C, away from direct sunlight.
Is the material safe for medical use?
Yes, the mattress is made of high-quality Medical PVC, which is durable, easy to clean, and meets medical nursing standards.

Related Products